Test Code CRTFR Creatinine, Random, Urine
Specimen Required
Only orderable as part of a profile. For more information see:
-RLTE4 / Leukotriene E4, Random, Urine.
-TIUCR / Titanium/Creatinine Ratio, Random, Urine
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Container/Tube: Plastic, 5-mL tube
Specimen Volume: 5 mL
Collection Instructions:
1. Collect a random urine specimen.
2. No preservative.
Useful For
Normalizing urinary analytes to account for the variation in urinary concentrations between individuals when using random urine collections
Method Name
Only orderable as part of a profile. For more information see:
-RLTE4 / Leukotriene E4, Random, Urine.
-TIUCR / Titanium/Creatinine Ratio, Random, Urine
Enzymatic Colorimetric Assay
Reporting Name
Creatinine, Random, USpecimen Type
UrineSpecimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Frozen (preferred) | 30 days | |
Refrigerated | 30 days | ||
Ambient | 14 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Clinical Information
Creatinine is formed from the metabolism of creatine and phosphocreatine, both of which are principally found in muscle. Thus, the amount of creatinine produced is, in large part, dependent upon the individual's muscle mass and tends not to fluctuate much from day-to-day.
Creatinine is not protein bound and is freely filtered by glomeruli. All filtered creatinine is excreted in the urine. Renal tubular secretion of creatinine contributes a small proportion of excreted creatinine. Although most excreted creatinine is derived from an individual's muscle mass, dietary protein intake, particularly of cooked meat, can contribute to urinary creatinine levels.
The renal clearance of creatinine provides an estimate of glomerular filtration rate. Since creatinine in the urine only comes mainly from filtration, the concentration of creatinine reflects overall urinary concentration. Therefore, creatinine can be used to normalize other analytes in a random urine specimen.
Reference Values
Only orderable as part of a profile. For more information see:
-RLTE4 / Leukotriene E4, Random, Urine.
-TIUCR / Titanium/Creatinine Ratio, Random, Urine
≥18 years old: 16-326 mg/dL
Reference values have not been established for patients who are younger than 18 years of age.
Interpretation
Decreased creatinine clearance indicates decreased glomerular filtration rate. This can be due to conditions, such as progressive kidney disease, or result from adverse effect on renal hemodynamics that are often reversible, including certain drugs or from decreases in effective renal perfusion (eg, volume depletion or heart failure).
Increased creatinine clearance is often referred to as "hyperfiltration" and is most frequently seen during pregnancy or in patients with diabetes mellitus before diabetic nephropathy has occurred. It may also occur with large dietary protein intake.
Cautions
Intraindividual variability in creatinine excretion may be due to differences in muscle mass or amount of ingested meat.
Acute changes in glomerular filtration rate, before a steady state has developed, will alter the amount of urinary creatinine excreted.
Clinical Reference
1. Delaney MP, Lamb EJ. Kidney disease. In: Rifai N, Horvath AR, Wittwer CT, eds: Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. 6th ed. Elsevier; 2018:1256-1323
2. Meeusen JW, Rule AD, Voskoboev N, Baumann NA, Lieske JC. Performance of cystatin C- and creatinine-based estimated glomerular filtration rate equations depends on patient characteristics. Clin Chem. 2015;61(10):1265-1272. doi:10.1373/clinchem.2015.243030
3. Newman DJ, Price CP. Renal function and nitrogen metabolites. In: Burtis CA, Ashwood ER, eds. Tietz Textbook of Clinical Chemistry. 3rd ed. WB Saunders Company; 1999:1204-1270
4. Kasiske BL, Keane WF: Laboratory assessment of renal disease: clearance, urinalysis, and renal biopsy. In: Brenner BM, ed. The Kidney. 6th ed. WB Saunders Company; 2000:1129-1170
Method Description
This enzymatic method is based on the determination of sarcosine from creatinine with the aid of creatininase, creatinase, and sarcosine oxidase. The liberated hydrogen peroxide is measured via a modified Trinder reaction using a colorimetric indicator. Optimization of the buffer system and the colorimetric indicator enables the creatinine concentration to be quantified both precisely and specifically.(Package insert: Creatinine plus ver 2. Roche Diagnostics; V15.0, 03/2019)
Day(s) Performed
Monday through Sunday
Report Available
1 daySpecimen Retention Time
7 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
82570
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
CRTFR | Creatinine, Random, U | 2161-8 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
CRTFR | Creatinine, Random, U | 2161-8 |