Sign in →

Browse by Name

  1. A
  2. B
  3. C
  4. D
  5. E
  6. F
  7. G
  8. H
  9. I
  10. J
  11. K
  12. L
  13. M
  14. N
  15. O
  16. P
  17. Q
  18. R
  19. S
  20. T
  21. U
  22. V
  23. W
  24. X
  25. Y
  26. Z
  27. #
 

Mayo Clinic Laboratories

Test Code GT3 GLUCOSE TOLERANCE 3HR,GEST

Important Note

3 hour Glucose Tolerance tests must be scheduled with Porter Laboratory

Please call 802-388-4747 to schedule.

See Gestational Screening and 3 hour test in Resources for more information.

Additional Codes

LAB2183

Performing Laboratory

Porter Hospital Laboratory

Specimen Requirements

Specimen Type:  Blood

Container/Tube:  Grey

Also Acceptable:  tiger top; lithium heparin (green)

Specimen Volume:  Full tube, submit 0.4 mL plasma/serum
Specimen Minimum Volume: 0.35 mL
Collection Instructions:
    1. Send specimen in original tube.
    2. If there is a delay in transport of >1 hour, centrifuge tube.
    3. Centrifuged SERUM samples are stable for:
        • 8 hours at room temperature
        • 7 days at 2-8 °C

Centrifuged PLASMA samples are stable for:
     • 8 hours at room temperature
     • 72 hours at 2-8°C

Specimen Transport Temperature

Refrigerated

Test Schedule / Analytical Time / Test Priority / Turn Around Time

Monday – Friday / Not Available STAT / Routine - 4 hours

Test Classification and CPT Coding

82951 & 82952

Normal Reference Values

See report.

Critical Values

*New range as of 3/17/2025

*0 - 18 years:  <50 and >300 mg/dL

18 years and up:  ≤55 and >500 mg/dL