Test Code LAB3356 SSA/SSB ANTIBODY PANEL
Specimen Information
Container | Specimen | Temperature | Collect Vol | Submit Vol | Min Vol | Stability |
SST | Serum | Refrigerate | 2 mL | 1 mL | 0.5 mL | 48 hours |
SST | Serum | Frozen | 2 mL | 1 mL | 0.5 mL | 1 month |
Serum should be separated from the clot within 4 hours of collection. Store samples at room temperature no longer than 8 hours. If the assay will not be completed within 8 hours, refrigerate the sample at 2-8C. If the assay will not be completed within 48 hours, or for shipment of the sample, freeze at -20C or lower.
Reference Range
For Ro52, Ro60, and SS-B (all ages):
Negative: <20 CU
Positive: ≥20 CU
Method
Chemiluminescent Immunoassay
Instrumentation
Werfen Bioflash
CPT Code(s)
Description | CPT Code |
SS-B (La) Ab, IgG | 86235 |
Ro52 Ab, IgG | 86235 |
Ro60 Ab, IgG | 86235 |
Performing Location
University of Vermont Medical Center
Test Schedule / Analytical Time / Test Priority
Monday - Friday / Same day / Not available STAT
Section
Immunology
Is the UVMMC lab NY State Certified to perform this testing? Yes/No
Yes