Test Code RET RETICULOCYTE COUNT
Additional Codes
LAB296
Performing Laboratory
Porter Hospital Laboratory
Specimen Requirements
Specimen Type: Whole blood
Container/Tube: Lavender (EDTA)
Specimen Volume: 1 full tube
Specimen Minimum Volume: 1.0 mL
Collection Instructions:
1. Tube must at least 1/2 full.
2. Send specimen in original tube, unspun, room temperature or refrigerated.
3. Sample stable 24 hours at room temperature and 48 hours refrigerated.
Transport Temperature
Refrigerate
Test Classification and CPT Code
85045
Test Schedule / Analytical Time / Test Priority / Turn Around Time
Daily / Same Day / Available STAT / Routine - 4 Hours
STAT - 60 Minutes
Methodology
Automated Cell Counter
Normal Reference Range:
0.5-1.8%
Critical Value
None Established