Sign in →

Test Code SMPU Monoclonal Protein Screen, 24 Hour, Urine


Shipping Instructions


Refrigerate specimen during collection and send refrigerated.



Necessary Information


24-Hour volume (in milliliters) is required.



Specimen Required


Supplies: Urine Container, 60 mL (T313)

Submission Container/Tube: Plastic, 60-mL urine bottle

Specimen Volume: 50 mL

Collection Instructions:

1. Collect urine for 24 hours.

2. Aliquot between 30 mL and 50 mL of urine into a plastic, 60-mL urine bottle.

Additional Information: See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens for multiple collections.


Useful For

Monitoring patients with monoclonal gammopathies

Profile Information

Test ID Reporting Name Available Separately Always Performed
MPTU M-protein Mass-Fix, 24 HR, U No Yes
PTU3 Protein, Total, 24 HR, U Yes Yes

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
PEU Protein Electrophoresis, 24 Hr, U No No

Testing Algorithm

Testing for urine monoclonal proteins (M-proteins) with mass-fix alone is not considered adequate screening for monoclonal gammopathies.

 

The laboratory will evaluate the urine for M-proteins using the mass-fix method, and if positive for M-protein, protein electrophoresis will be performed at an additional charge.

 

The following algorithms are available:

-Amyloidosis: Laboratory Approach to Diagnosis

-Multiple Myeloma: Laboratory Screening

Method Name

PTU3: Turbidimetry

PEU: Agarose Gel Electrophoresis

MPTU: Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS)

Reporting Name

M-protein Screen, 24 HR, U

Specimen Type

Urine

Specimen Minimum Volume

30 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 14 days
  Frozen  5 days
  Ambient  24 hours

Reject Due To

  All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Clinical Information

Urine proteins can be grouped into 5 fractions by protein electrophoresis:

-Albumin

-Alpha-1

-Alpha-2

-Beta-globulin

-Gamma-globulin 

One or more quantifiable monoclonal proteins may be present and reported as M spike.

 

The urine total protein concentration, the electrophoretic pattern, and the presence of a monoclonal immunoglobulin light chain may be characteristic of monoclonal gammopathies such as multiple myeloma, primary systemic amyloidosis, and light chain deposition disease.

 

The following algorithms are available:

-Amyloidosis: Laboratory Approach to Diagnosis

-Multiple Myeloma: Laboratory Screening

Reference Values

PROTEIN, TOTAL

<229 mg/24 hours

 

Reference values have not been established for patients younger than 18 years of age.

 

ELECTROPHORESIS, PROTEIN

The following fractions, if present, will be reported as mg/24 hours:

Albumin

Alpha-1-globulin

Alpha-2-globulin

Beta-globulin

Gamma-globulin

 

MASS-FIX M-PROTEIN ISOTYPE

M-protein Isotype MS:

No monoclonal protein detected

 

Flag M-protein Isotype MS:

Negative

Interpretation

The presence of a monoclonal immunoglobulin light chain in the urine is seen in multiple myeloma, macroglobulinemia, primary systemic amyloidosis and light-chain deposition disease, monoclonal gammopathy of undetermined significance, and idiopathic Bence-Jones proteinuria. The presence of a monoclonal light chain can produce renal insufficiency, may be deposited as amyloid fibrils, may damage the proximal tubes producing Fanconi syndrome, or light chains may deposit in the glomerulus and cause light-chain deposition disease.

 

Heavy-chain fragments as well as light chains may be seen in the urine of patients with multiple myeloma or amyloidosis.

Cautions

Monoclonal gammopathies are rarely seen in patients younger than 30 years of age.

 

Hemolysis may cause a discrete band on protein electrophoresis, which will be negative on isotyping.

 

Penicillin may split the albumin band.

 

Radiographic agents may produce an uninterpretable pattern.

Clinical Reference

1. Abraham RS, Barnidge DR: Protein analysis in the clinical immunology laboratory. In: Detrick BD, Hamilton RG, Schmitz JL eds. Manual of Molecular and Clinical Laboratory Immunology. 8th ed. 2016:chap 4

2. Sykes E, Posey Y: Immunochemical characterization of immunoglobulins in serum, urine, and cerebrospinal fluid. In: Detrick B, Hamilton RG, Schmitz JL, eds. Molecular and Clinical Laboratory Immunology. 8th ed. Wiley; 2016:chap 9

Method Description

Protein:

The sample is preincubated in an alkaline solution containing EDTA, which denatures the protein and eliminates interference from magnesium ions. Benzethonium chloride is then added, producing turbidity.(Package insert: Total Protein Urine/CSF. Roche Diagnostics; V13.0, 11/2018)

 

Electrophoresis:

Urine proteins are separated in an electric field according to their size, shape, and electric charge (Helena SPIFE Touch). The separation is performed on agarose gels. The proteins are visualized by staining with acid blue and the intensity of staining is quantitated by densitometry (Helena Quick Scan Touch). Multiplying by the urine protein concentration converts the percentage of protein in each fraction into urine concentration.(Instruction manual: Helena SPIFE Touch. Helena Laboratories, Corp; 11/2016; package insert: Helena SPIFE Touch SPE Pro 277. Helena Laboratories, Corp; 06/2018; Keren DF, Humphrey RL: Clinical indications and applications of serum and urine protein electrophoresis. In: Detrick BD, Hamilton RG, Schmitz JL eds. Manual of Molecular and Clinical Laboratory Immunology. 8th ed. 2016:chap 8)

 

Mass-Fix:

Mass-Fix M-protein isotype by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is performed with immunoaffinity purification followed by MALDI-TOF MS analysis. For the immunoaffinity purification, patient sample is applied to 5 separate immunoaffinity resins (CaptureSelect, Life Sciences) specific to immunoglobulin G, A, M, K, and L. Unbound protein is washed away and the isolated immunoglobulins are reduced to separate the heavy and light chains subunits to be analyzed via MALDI-TOF MS. The 5 separate spectra from each patient immunopurification are overlaid and investigated for an overabundance of immunoglobulin and immunoglobulin light chain.(Milani P, Murray DL, Barnidge DR, et al: The utility of MASS-FIX to detect and monitor monoclonal proteins in the clinic. Am J Hematol. 2017 Aug;92(8):772-779. doi: 10.1002/ajh.24772)

Day(s) Performed

Monday through Friday

Report Available

4 to 6 days

Specimen Retention Time

See Individual Test IDs

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

84156

84166 Electrophoresis, protein (if appropriate)

0077U

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SMPU M-protein Screen, 24 HR, U In Process

 

Result ID Test Result Name Result LOINC Value
617117 M-protein Isotype MS, 24 HR, U In Process
TP6 Total Protein, 24 HR, U 2889-4
TM24 Collection Duration 13362-9
617118 Flag M-protein Isotype MS, 24 HR, U No LOINC Needed
VL92 Urine Volume 3167-4

NY State Approved

Yes

Urine Preservative Collection Options

Note: The addition of preservative or application of temperature controls must occur within 4 hours of completion of the collection.

Ambient

OK

Refrigerate

Preferred

Frozen

OK

50% Acetic Acid

No

Boric Acid

No

Diazolidinyl Urea

OK

6M Hydrochloric Acid

No

6M Nitric Acid

No

Sodium Carbonate

No

Thymol

OK

Toluene

No