Sign in →

Test Code T&H TYPE & HOLD

Important Note

Use for Pre OP specimens.

 

Additional Codes

LAB895

ABO/RH TYPE will be performed

Performing Laboratory

Porter Hospital Laboratory

Specimen Requirements

Specimen Type: Whole blood

Container/Tube: Pink top (EDTA) or Red Top

Specimen Volume: 7 mL

Specimen Minimum Volume: 3.5 mL

Collection Instructions:

1. Send specimen in original tube.

 

Specimen Transport Temperature

Refrigerate

Test Classification and CPT Coding

86900, 86901

Test Schedule / Analytical Time / Test Priority / Turn around Time

Daily / 24 Hours / Available STAT / Routine - 4 Hours

                                                      STAT - 60 Minutes

Methodology

Agglutination by Tube Test

Reporting

The sample is held 72 hours for possible additional orders. The reason it is held only 72 hours is because the antibody screen test must be completed within 72 hours of blood collection. If the additional orders are received after 72 hours, a new sample will need to be obtained.